509 laboratories fulfill all search criteria, fulfilled search criteria are marked with a check mark. List sorted by name, grouped by country
Detailed information about the laboratory
Number Anechoic Rooms
2
Dimensions of the Largest Anechoic Room
10 m x 7 m x 6 m
Distance Between Test Object and Antenna
3 m
Number of FEM/GTEM Cells
1
Number of Shielded Rooms
4
EMC
yes
CE
yes
FCC
yes
Development Accompanying
yes
Production Accompanying
no
Notified Body
no
Accredited Laboratory
yes
Automotive Electronics
yes
Medical Technology
yes
Industrial Electronics
yes
Aerospace, Military
yes
Telecommunications
yes
Consumer/Household Technology
yes
Radio Technology
yes
Emission
yes
Interference Resistance
yes
CE Relevant
yes
At the customer
no
Free-field Measurement
yes
Network Analysis
no
Environmental Simulation
yes
Others
Detailed information about the laboratory
Number Anechoic Rooms
5
Dimensions of the Largest Anechoic Room
11x7x6
Distance Between Test Object and Antenna
3 Meters
Number of FEM/GTEM Cells
2
Number of Shielded Rooms
0
EMC
yes
CE
yes
FCC
yes
Development Accompanying
yes
Production Accompanying
yes
Notified Body
yes
Accredited Laboratory
yes
Automotive Electronics
yes
Medical Technology
yes
Industrial Electronics
yes
Aerospace, Military
yes
Telecommunications
yes
Consumer/Household Technology
yes
Radio Technology
yes
Emission
yes
Interference Resistance
yes
CE Relevant
yes
At the customer
yes
Free-field Measurement
yes
Network Analysis
yes
Environmental Simulation
yes
Others
Detailed information about the laboratory
Number Anechoic Rooms
2
Dimensions of the Largest Anechoic Room
9X6X6 and 7X3X3
Distance Between Test Object and Antenna
3 meter
Number of FEM/GTEM Cells
1
Number of Shielded Rooms
0
EMC
yes
CE
yes
FCC
yes
Development Accompanying
yes
Production Accompanying
yes
Notified Body
no
Accredited Laboratory
yes
Automotive Electronics
no
Medical Technology
yes
Industrial Electronics
yes
Aerospace, Military
no
Telecommunications
yes
Consumer/Household Technology
yes
Radio Technology
yes
Emission
yes
Interference Resistance
yes
CE Relevant
yes
At the customer
yes
Free-field Measurement
no
Network Analysis
no
Environmental Simulation
yes
Others
Detailed information about the laboratory
Number Anechoic Rooms
3
Dimensions of the Largest Anechoic Room
10.8 x 7.2 x 6m
Distance Between Test Object and Antenna
3m, 5m
Number of FEM/GTEM Cells
1
Number of Shielded Rooms
7
EMC
yes
CE
yes
FCC
yes
Development Accompanying
yes
Production Accompanying
no
Notified Body
no
Accredited Laboratory
yes
Automotive Electronics
yes
Medical Technology
yes
Industrial Electronics
yes
Aerospace, Military
yes
Telecommunications
yes
Consumer/Household Technology
yes
Radio Technology
no
Emission
yes
Interference Resistance
yes
CE Relevant
yes
At the customer
yes
Free-field Measurement
yes
Network Analysis
no
Environmental Simulation
no
Others
Detailed information about the laboratory
Number Anechoic Rooms
4
Dimensions of the Largest Anechoic Room
22 x 14 x 10 m
Distance Between Test Object and Antenna
10 m
Number of FEM/GTEM Cells
0
Number of Shielded Rooms
6
EMC
yes
CE
yes
FCC
yes
Development Accompanying
yes
Production Accompanying
no
Notified Body
no
Accredited Laboratory
yes
Automotive Electronics
yes
Medical Technology
yes
Industrial Electronics
yes
Aerospace, Military
yes
Telecommunications
yes
Consumer/Household Technology
yes
Radio Technology
yes
Emission
yes
Interference Resistance
yes
CE Relevant
yes
At the customer
yes
Free-field Measurement
yes
Network Analysis
no
Environmental Simulation
yes
Others
Electrical safety and SAR
Detailed information about the laboratory
Number Anechoic Rooms
2
Dimensions of the Largest Anechoic Room
12x7.4x4 m
Distance Between Test Object and Antenna
3-7 m
Number of FEM/GTEM Cells
0
Number of Shielded Rooms
4
EMC
yes
CE
yes
FCC
yes
Development Accompanying
yes
Production Accompanying
no
Notified Body
no
Accredited Laboratory
yes
Automotive Electronics
yes
Medical Technology
yes
Industrial Electronics
yes
Aerospace, Military
yes
Telecommunications
yes
Consumer/Household Technology
yes
Radio Technology
no
Emission
yes
Interference Resistance
yes
CE Relevant
yes
At the customer
yes
Free-field Measurement
yes
Network Analysis
no
Environmental Simulation
no
Others
Detailed information about the laboratory
Number Anechoic Rooms
-
Dimensions of the Largest Anechoic Room
-
Distance Between Test Object and Antenna
-
Number of FEM/GTEM Cells
1
Number of Shielded Rooms
-
EMC
yes
CE
yes
FCC
yes
Development Accompanying
yes
Production Accompanying
yes
Notified Body
no
Accredited Laboratory
no
Automotive Electronics
yes
Medical Technology
yes
Industrial Electronics
yes
Aerospace, Military
yes
Telecommunications
yes
Consumer/Household Technology
yes
Radio Technology
no
Emission
yes
Interference Resistance
yes
CE Relevant
yes
At the customer
yes
Free-field Measurement
no
Network Analysis
no
Environmental Simulation
no
Others
Detailed information about the laboratory
Number Anechoic Rooms
1
Dimensions of the Largest Anechoic Room
-
Distance Between Test Object and Antenna
3
Number of FEM/GTEM Cells
0
Number of Shielded Rooms
1
EMC
yes
CE
yes
FCC
yes
Development Accompanying
yes
Production Accompanying
no
Notified Body
no
Accredited Laboratory
no
Automotive Electronics
yes
Medical Technology
yes
Industrial Electronics
yes
Aerospace, Military
yes
Telecommunications
yes
Consumer/Household Technology
yes
Radio Technology
yes
Emission
yes
Interference Resistance
yes
CE Relevant
yes
At the customer
yes
Free-field Measurement
yes
Network Analysis
no
Environmental Simulation
yes
Others
Detailed information about the laboratory
Number Anechoic Rooms
1
Dimensions of the Largest Anechoic Room
7,4 x 3,8 x 3,6m
Distance Between Test Object and Antenna
3m
Number of FEM/GTEM Cells
0
Number of Shielded Rooms
1
EMC
yes
CE
yes
FCC
yes
Development Accompanying
yes
Production Accompanying
yes
Notified Body
no
Accredited Laboratory
no
Automotive Electronics
no
Medical Technology
no
Industrial Electronics
yes
Aerospace, Military
no
Telecommunications
yes
Consumer/Household Technology
yes
Radio Technology
no
Emission
yes
Interference Resistance
yes
CE Relevant
yes
At the customer
yes
Free-field Measurement
no
Network Analysis
no
Environmental Simulation
yes
Others
Detailed information about the laboratory
Number Anechoic Rooms
-
Dimensions of the Largest Anechoic Room
-
Distance Between Test Object and Antenna
-
Number of FEM/GTEM Cells
-
Number of Shielded Rooms
-
EMC
yes
CE
yes
FCC
yes
Development Accompanying
yes
Production Accompanying
yes
Notified Body
no
Accredited Laboratory
yes
Automotive Electronics
yes
Medical Technology
yes
Industrial Electronics
yes
Aerospace, Military
yes
Telecommunications
yes
Consumer/Household Technology
yes
Radio Technology
no
Emission
yes
Interference Resistance
yes
CE Relevant
yes
At the customer
yes
Free-field Measurement
no
Network Analysis
no
Environmental Simulation
no
Others
Detailed information about the laboratory
Number Anechoic Rooms
2
Dimensions of the Largest Anechoic Room
7,05m x 3,15m x 3,05m
Distance Between Test Object and Antenna
3m
Number of FEM/GTEM Cells
1
Number of Shielded Rooms
2
EMC
yes
CE
yes
FCC
no
Development Accompanying
yes
Production Accompanying
yes
Notified Body
yes
Accredited Laboratory
yes
Automotive Electronics
yes
Medical Technology
yes
Industrial Electronics
yes
Aerospace, Military
yes
Telecommunications
yes
Consumer/Household Technology
yes
Radio Technology
yes
Emission
yes
Interference Resistance
yes
CE Relevant
yes
At the customer
yes
Free-field Measurement
no
Network Analysis
no
Environmental Simulation
no
Others
Detailed information about the laboratory
Number Anechoic Rooms
2/1
Dimensions of the Largest Anechoic Room
6.5m x 3.8m x 2.8m
Distance Between Test Object and Antenna
3m
Number of FEM/GTEM Cells
1
Number of Shielded Rooms
1
EMC
yes
CE
yes
FCC
yes
Development Accompanying
yes
Production Accompanying
no
Notified Body
no
Accredited Laboratory
no
Automotive Electronics
no
Medical Technology
yes
Industrial Electronics
yes
Aerospace, Military
yes
Telecommunications
yes
Consumer/Household Technology
yes
Radio Technology
no
Emission
yes
Interference Resistance
yes
CE Relevant
yes
At the customer
no
Free-field Measurement
no
Network Analysis
yes
Environmental Simulation
no
Others
Detailed information about the laboratory
Number Anechoic Rooms
1
Dimensions of the Largest Anechoic Room
7,3 m x 3,4 m x 3,3 m
Distance Between Test Object and Antenna
3 m
Number of FEM/GTEM Cells
-
Number of Shielded Rooms
1
EMC
yes
CE
yes
FCC
no
Development Accompanying
yes
Production Accompanying
no
Notified Body
no
Accredited Laboratory
no
Automotive Electronics
no
Medical Technology
yes
Industrial Electronics
yes
Aerospace, Military
no
Telecommunications
yes
Consumer/Household Technology
yes
Radio Technology
no
Emission
yes
Interference Resistance
yes
CE Relevant
yes
At the customer
yes
Free-field Measurement
no
Network Analysis
no
Environmental Simulation
no
Others
Detailed information about the laboratory
Number Anechoic Rooms
1
Dimensions of the Largest Anechoic Room
6,7m x 3m x 3m
Distance Between Test Object and Antenna
3m
Number of FEM/GTEM Cells
1
Number of Shielded Rooms
1
EMC
yes
CE
yes
FCC
no
Development Accompanying
yes
Production Accompanying
yes
Notified Body
yes
Accredited Laboratory
no
Automotive Electronics
no
Medical Technology
yes
Industrial Electronics
yes
Aerospace, Military
no
Telecommunications
yes
Consumer/Household Technology
yes
Radio Technology
no
Emission
yes
Interference Resistance
yes
CE Relevant
yes
At the customer
no
Free-field Measurement
no
Network Analysis
yes
Environmental Simulation
yes
Others
Detailed information about the laboratory
Number Anechoic Rooms
1
Dimensions of the Largest Anechoic Room
-
Distance Between Test Object and Antenna
3
Number of FEM/GTEM Cells
0
Number of Shielded Rooms
1
EMC
yes
CE
yes
FCC
no
Development Accompanying
yes
Production Accompanying
yes
Notified Body
no
Accredited Laboratory
no
Automotive Electronics
no
Medical Technology
yes
Industrial Electronics
yes
Aerospace, Military
no
Telecommunications
yes
Consumer/Household Technology
yes
Radio Technology
no
Emission
yes
Interference Resistance
no
CE Relevant
yes
At the customer
no
Free-field Measurement
no
Network Analysis
yes
Environmental Simulation
no
Others