Topologie | Sperrwandler |
Eingangsspannung | 85-265 V |
Schaltfrequenz | 40-50 kHz |
Ausgang 1 | 0.35 A |
IC-Revision | 1.01 |
The MP44011 is a boundary-conduction–mode PFC controller with an internal-harmonic–injection function. It provides simple and highperformance active power-factor correction with minimal external components.
Compared against traditional boundaryconduction–mode PFC controllers, the harmonic-injection function makes the part suitable for LED lighting applications.
In LED lighting applications with two-stage structures, the harmonic-injection function can effectively reduce bus capacitance between theAC/DC and the DC/DC stage. In addition,harmonic injection can reduce the transformer size to save board space and BOM cost.
Also, the benefits of a harmonic-injection function also apply to general boost or flyback PFC applications.
The MP44011 is derived from the MP44010,except with a harmonic-injection function.
The MP44011 is available in an 8-pin SOIC package.
Remarks
Artikel Nr. | Datenblatt | Simulation | Downloads | Status | Produktserie | IR (A) | L (µH) | RDC max. (mΩ) | VR (V (AC)) | VT (V (AC)) | Material | L (mm) | W (mm) | H (mm) | Montageart | Muster | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
744841247 | SPEC | 8 Dateien | Aktiv i| Produktion ist aktiv. Erwartete Lebenszeit: >10 Jahre. | WE-CMB NiZn Stromkompensierte Netzdrossel | 2 | 47 | 40 | 250 | 1500 | NiZn | 16 | 7.5 | 17.5 | THT |
Muster |
---|
Artikel Nr. | Datenblatt | Simulation | Downloads | Status | Produktserie | IR (A) | L (µH) | RDC max. (mΩ) | VR (V (AC)) | VT (V (AC)) | Material | L (mm) | W (mm) | H (mm) | Montageart | Muster |
---|