Topology | Flyback Converter |
Input voltage | 90-265 V |
Switching frequency | 54-66 kHz |
Output 1 | 5 V / 2.4 A |
IC revision | 5 |
The device is an off-line converter with an 800 V rugged power section, a PWM control, two levels of over-current protection, overvoltage andoverload protections, hysteretic thermal protection, soft-start and safe auto-restart after any fault condition removal. Burst mode operationand device very low consumption help to meet the standby energy saving regulations.
Advance frequency jittering reduces EMI filter cost. Brown-out function protects the switch mode ower supply when the rectified input voltagelevel is below the normal minimum level specified for the system. The high voltage start-up circuit is embedded in the device.
Order Code | Datasheet | Simulation | Downloads | Status | Product series | VIN | VOut1 (V) | IOut1 (A) | Vaux (V) | VT (V (AC)) | fswitch (kHz) | L (mH) | NPRI : NSEC : NAUX | L (mm) | W (mm) | H (mm) | Mount | Size | Samples | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
750871111 | SPEC | 10 files | Active i| Production is active. Expected lifetime: >10 years. | WE-OLSTM Offline Flyback Transformers | 85 - 272 V (AC) | 5 | 2.4 | 12 | 4000 | 60 | 1.7 | 13.9:1:2.6 | 21 | 25 | 16 | THT | EE20/10/6 |
Samples |
---|
Order Code | Datasheet | Simulation | Downloads | Status | Product series | VIN | VOut1 (V) | IOut1 (A) | Vaux (V) | VT (V (AC)) | fswitch (kHz) | L (mH) | NPRI : NSEC : NAUX | L (mm) | W (mm) | H (mm) | Mount | Size | Samples |
---|